Trescal
Barcelona ASSI - Spain
ASSI Sistemas e Instrumentación, SL, Calle Ramón Martí i Alsina 2-6, plantas 2 y 3. 08911 Badalona
Opening hours
Mon
8:00AM - 5:30PM
Tue
8:00AM - 5:30PM
Wed
8:00AM - 5:30PM
Thu
8:00AM - 5:30PM
Fri
8:00AM - 3:00PM
Contact
+34 93 540 03 48

Our Barcelona ASSI validation, qualification and calibration lab specializes in life sciences It guarantees compliance with current GxP regulations and compliance with public health and regulatory bodies. Its instrument calibration and repair services are accredited and/or certified in accordance with ISO/IEC 17025.

ACCREDITATIONS

CAPABILITIES
Accredited Capabilities
Non-accredited Capabilities
Accelerometry
Dimensional
Electricity/Magnetism
Mass / Scale
Pressure / Vacuum
Temperature
Time/Frequency
Torque
Volume
Thermal and climatic testing
Optics
Accelerometry

Centrifugas y Agitadores

100 rpm ≤ ω < 1000 rpm
1000 rpm ≤ ω < 10000 rpm
10000 rpm ≤ ω ≤ 50000 rpm

Dimensional

LONGITUD

Bloques patrón longitudinales Calidad 2

100 mm < L ≤ 300 mm

Barras patrón de extremos

L ≤ 200 mm

Alexómetros de dos contactos E = 0,001 mm

L ≤ 10 mm
10 mm < L ≤ 30 mm
30 mm < L ≤ 100 mm

Alexómetros de dos contactos E > 0,001 mm

L ≤ 100 mm

Bolas y esferas patrón

1 mm ≤ D ≤ 50 mm

Cabeza micrométrica E ≤ 0,001 mm

L ≤ 50 mm
50 mm < L ≤ 75 mm

Calibres de diámetro exterior
e interior

D ≤ 200 mm
(Ø Exterior)
2,5 mm ≤ D ≤ 200 mm
(Ø Interior)

Comparadores mecánicos,
electrónico y palpadores de
palanca E = 0,001 mm

L < 10 mm
10 mm ≤ L ≤ 30 mm
30 mm < L ≤ 100 mm

Comparadores mecánicos,
electrónico y palpadores de
palanca E > 0,001 mm

L ≤ 100 mm

Láminas patrón de espesores de acero

0,005 mm ≤ L ≤ 2 mm
2 mm < L ≤ 3 mm

Láminas patrón de espesores de plástico

0,005 mm ≤ L ≤ 3 mm

Medidor de espesor por
ultrasonidos

0 ≤ L ≤ 100 mm

Medidores de espesores de
recubrimiento

L ≤ 200 µm
200 µm ≤ L ≤ 3000 µm

Micrómetros de exteriores
0,001 mm ≤ E ≤ 0,002 mm

L < 200 mm
200 mm ≤ L ≤300 mm
300 mm ≤ L ≤1000 mm

Micrómetros de exteriores
0,001 mm ≤ E ≤ 0,002 mm

L < 150 mm
150 mm ≤ L ≤ 300 mm
300 mm ≤ L ≤ 1000 mm

Micrómetros de exteriores
E = 0,005mm

L ≤ 500 mm
500 mm < L ≤ 1000 mm

Micrómetros de exteriores E ≤ 0,01mm

L ≤ 1000 mm

Micrómetros de interiores
0,001 mm ≤ E ≤ 0,002mm

L < 150 mm
200 mm ≤ L ≤ 300 mm

Micrómetros de interiores
0,001 mm ≤ E ≤ 0,002mm

L < 150 mm
150 mm ≤ L ≤ 300 mm

Micrómetros de interiores
E > 0,002mm

L ≤ 300 mm

Micrómetros de interiores de tres contactos, con división de escala = 0,001 mm

2 mm ≤ L ≤ 100 mm
100 mm < L ≤ 200 mm

Micrómetros de interiores de tres contactos, con división de escala = 0,002 mm

2 mm ≤ L ≤ 100 mm
100 mm < L ≤ 200 mm

2 mm ≤ L ≤ 100 mm
100 mm < L ≤ 200 mm

Micrómetros de interiores de tres contactos, con división de escala > 0,002 mm

2 mm ≤ L ≤ 200 mm

Patrones cilíndricos interiores y exteriores

D ≤ 200 mm
(Ø Exterior)
2,5 mm ≤ D ≤ 200 mm
(Ø Interior)

Patrones de distancia exterior e interior

L ≤ 200 mm (Exterior)
2,5 mm ≤ L ≤ 200 mm (Interior)

Pies de rey E = 0,01 mm

L ≤ 1000 mm
1000 mm < L ≤ 1500 mm

Pies de rey E = 0,01 mm

L ≤ 1000 mm
1000 mm < L ≤ 1500 mm

Pies de rey
E > 0,01 mm

L ≤ 1500 mm

Proyector de perfiles Eje x, y
0,001 mm ≤ E < 0,01 mm

L < 100 mm
100 mm ≤ L ≤ 200 mm
200 mm < L ≤ 500 mm

Proyector de perfiles Eje x, y E ≤ 0,01 mm

L ≤ 500 mm

Regla vertical de trazos E ≥ 0,01 mm

L ≤ 1000 mm

Reglas de trazos, cintas métricas y flexómetros, con
división de escala = 0,5 mm

L ≤ 1 m

Reglas de trazos, cintas métricas y flexómetros, con
división de escala ≤ 1 mm

L ≤ 50 m

Sondas de regla, E ≤ 0,01 mm

L ≤ 1000 mm

Reglas digitales, E ≤ 0,01 mm

L ≤ 1000 mm

Sondas micrométricas, 0,001 mm ≤ E ≤ 0,002mm

L < 200 mm
200 mm ≤ L ≤ 300 mm

Sondas micrométricas, 0,001 mm ≤ E ≤ 0,002 mm

L < 150 mm
150 mm ≤ L ≤ 300 mm

Sondas micrométricas, con E > 0,002 mm

L ≤ 300 mm

Verificadores rápidos de interiores o exteriores E = 0,001 mm

L ≤ 150 mm
150 mm < L ≤ 200 mm

Verificadores rápidos de
interiores o exteriores E = 0,001 mm

L ≤ 150 mm
150 mm < L ≤ 200 mm

Verificadores rápidos de
interiores o exteriores E > 0,001 mm

L ≤ 200 mm

Útil de control o pieza medida con pie de rey o
micrómetro

Medición con pie de rey
0 ≤ L ≤ 200 mm
(L= Longitud)
Medición con micrómetro
0 ≤ L ≤ 25 mm
(L= Longitud)

Útiles de control y piezas (con Medidora de una coordenada horizontal)

L ≤ 200 mm
(L ó Ø Exterior)
2,5 mm ≤ L ≤ 200 mm
(L ó Ø Interior)

Comparadores mecánicos
E ≤ 0,01 mm

L ≤ 100 mm

PARÁMETROS DE ROSCA

Calibres tampón roscados
(cilíndricos) con perfil simétrico y ángulo de flancos
de 55° o 60° Ángulo de hélice
< 5°

2,5 mm ≤ D ≤ 200 mm
(paso 0,3 mm a 6 mm)
D = diámetro

Calibres anillo roscados (cilíndricos) con perfil simétrico y ángulo de flancos
de 55° o 60° Ángulo de hélice
< 5°

2,5 mm ≤ D ≤ 130 mm (paso 0,6 mm a 6 mm)
D = diámetro

ÁNGULO

Transportador de ángulos

0 ˚≤ α ≤ 360°

Nivel de medida, horizontalidad

α ≤ 10 mm/m

Niveles, Clinómetros E ≤ 0,01°

α ≤ 90°

Proyector de perfiles

0˚ ≤ α ≤ 360°

 

Electricity/Magnetism

TENSIÓN C.C.

Calibradores Generadores
Simuladores de temperatura

0 mV ≤ U ≤ 0,1 mV
0,1 mV < U < 200 mV
200 mV ≤ U < 2 V
2 V ≤ U < 20 V
20 V ≤ U < 200 V
200 V ≤ U ≤ 1020 V

Multímetros Medidores
Indicadores de temperatura

0 mV ≤ U ≤ 0,1 mV
0,1 mV < U < 200 mV
200 mV ≤ U < 2 V
2 V ≤ U < 20 V
20 V ≤ U < 200 V
200 V ≤ U ≤ 1020 V

Multímetros, Medidores, Indicadores genéricos con
entrada lineal de
Tensión C.C

0 mV ≤ U < 104 mV
104 mV ≤ U < 1,04 V
1,04 V ≤ U < 10,4 V
10,4 V ≤ U < 104 V
104 V ≤ U ≤ 1020 V

TENSIÓN C.A.

Calibradores. Generadores

10 mV ≤ U < 200 mV
40 Hz < f ≤ 100 Hz
100 Hz < f ≤ 2 kHz
2 kHz < f ≤ 10 kHz
10 kHz < f ≤ 3 kHz
30 kHz < f ≤ 100 kHz

200 mV ≤ U < 330 mV
40 Hz < f ≤ 100 Hz
100 Hz < f ≤ 2 kHz
2 kHz < f ≤ 10 kHz
10 kHz < f ≤ 30 kHz
30 kHz < f ≤ 100 kHz

330 mV ≤ U < 2 V
40 Hz ≤ f ≤ 100 Hz
100 Hz < f ≤ 2 kHz
2 kHz < f ≤ 10 kHz
10 kHz < f ≤ 30 kHz
30 kHz < f ≤ 100 kHz

2 V ≤ U < 20 V
40 Hz ≤ f ≤ 100 Hz
100 Hz < f ≤ 2 kHz
2 kHz < f ≤ 10 kHz
10 kHz < f ≤ 30 kHz
30 kHz < f ≤ 100 kHz
100 kHz < f ≤ 300 kHz
300 kHz < f ≤ 1 MHz

20 V ≤ U < 200 V
40 Hz ≤ f ≤ 100 Hz
100 Hz < f ≤ 2 kHz
2 kHz < f ≤ 10 kHz
10 kHz < f ≤ 30 kHz
30 kHz < f ≤ 100 kHz

200 V ≤ U ≤ 1000 V
50 Hz ≤ f ≤ 2 kHz

Multímetros. Medidores

10 mV ≤ U < 200 mV
40 Hz < f ≤ 100 Hz
100 Hz < f ≤ 2 kHz
2 kHz < f ≤ 10 kHz
10 kHz < f ≤ 30 kHz

200 mV ≤ U < 330 mV
40 Hz ≤ f ≤ 100 Hz
100 Hz < f ≤ 2 kHz
2 kHz < f ≤ 10 kHz
10 kHz < f ≤ 30 kHz

330 mV ≤ U < 2 V
40 Hz < f ≤ 100 Hz
100 Hz < f ≤ 2 kHz
2 kHz < f ≤ 10 kHz
10 kHz < f ≤ 30 kHz
30 kHz < f ≤ 100 kHz

2 V ≤ U < 20 V
40 Hz < f ≤ 100 Hz
100 Hz < f ≤ 2 kHz
2 kHz < f ≤ 10 kHz
10 kHz < f ≤ 30 kHz
30 kHz < f ≤ 100 kHz

20 V ≤ U < 200 V
40 Hz ≤ f ≤ 100 Hz
100 Hz < f ≤ 2 kHz
2 kHz < f ≤ 10 kHz
10 kHz < f ≤ 30 kHz
30 kHz < f ≤ 100 kHz

200 V ≤ U ≤ 1000 V
50 Hz ≤ f ≤ 2 kH

10 mV ≤ U < 104 mV
40 Hz ≤ f < 2kHz
2kHz ≤ f ≤ 20 kHz

104 mV ≤ U < 1,04 V
40 Hz ≤ f < 2kHz
2 kHz ≤ f ≤ 20 kHz

1,04 V ≤ U < 10,4 V
40 Hz ≤ f < 2kHz
2 kHz ≤ f ≤ 20 kHz

10,4 V ≤ U < 104 V
40Hz ≤ f ≤ 1 kHz

104 V ≤ U ≤ 1020 V
40 Hz ≤ f ≤ 1 kHz

INTENSIDAD C.C

Calibradores Generadores

0 µA ≤ I < 200 µA
200 µA ≤ I < 2 mA
2 mA ≤ I < 20 mA
20 mA ≤ I < 200 mA
200 mA ≤ I < 2 A
2 A ≤ I ≤ 20 A

Multímetros, Medidores, Pinzas Amperimétricas

0 µA ≤ I < 200 µA
200 µA ≤ I < 2 mA
2 mA ≤ I < 20 mA
20 mA ≤ I < 200 mA
200 mA ≤ I < 2 A
2 A ≤ I ≤ 20 A

Pinzas Amperimétricas

20 A < I ≤ 1000 A

Multímetros, Medidores, Indicadores genéricos con
entrada lineal de Intensidad C.C.

0 µA ≤ I < 0,1 µA
0,1 µA ≤ I < 104 µA
0,104 mA ≤ I < 1,04 mA
1,04mA ≤ I < 10,4 mA
10,4 mA ≤ I < 104 mA
104 mA ≤ I < 1,04 A
1,04 A ≤ I ≤ 10 A

Pinzas Amperimétricas

10 A < I ≤ 500 A

INTENSIDAD C.A.

Calibradores Generadores

100 µA ≤ I < 200 µA
40 Hz ≤ f ≤ 10 kHz
200 µA ≤ I < 2 mA
40 Hz ≤ f ≤ 10 kHz
2 mA ≤ I < 20 mA
40 Hz ≤ f ≤ 10 kHz
20 mA ≤ I < 200 mA
40 Hz ≤ f ≤ 10 kHz
200 mA ≤ I < 2 A
40 Hz ≤ f ≤ 2 kHz
2 kHz < f ≤ 10 kHz
2 A ≤ I ≤ 20 A
40 Hz ≤ f ≤ 2 kHz
2 kHz < f ≤ 5 kHz

Multímetros, Medidores
Pinzas, Amperimétricas

100 µA ≤ I < 200 µA
40 Hz ≤ f ≤ 10 kHz
200 µA ≤ I < 2 mA
40 Hz ≤ f ≤ 10 kHz
2 mA ≤ I < 20 mA
40 Hz ≤ f ≤ 10 kHz
20 mA ≤ I < 200 mA
40 Hz ≤ f ≤ 10 kHz
200 mA ≤ I < 2 A
40 Hz ≤ f ≤ 2 kHz
2 kHz < f ≤ 10 kHz
2 A ≤ I ≤ 20 A
40 Hz ≤ f ≤ 2 kHz
2 kHz < f ≤ 5 kHz

Pinzas Amperimétricas

20 A < I ≤ 1000 A
f = 50 Hz

Multímetros, Medidores

I = 100 µA
40 Hz ≤ f ≤ 2 kHz
0,104 mA ≤ I < 1,04 mA
40 Hz ≤ f ≤ 2 kHz
1,04 mA ≤ I < 10,4 mA
40 Hz ≤ f ≤ 2 kHz
10,4 mA ≤ I < 104 mA
40 Hz ≤ f ≤ 2 kHz
104 mA ≤ I < 1,04 A
40 Hz ≤ f ≤ 2 kHz
1,04 A ≤ I ≤ 10,4 A
40 Hz ≤ f ≤ 2 kHz

Pinzas Amperimétricas

10 A < I ≤ 500 A
50 Hz

RESISTENCIA C.C.

Calibradores, Generadores, Simuladores de temperatura por termoresistencia

0 Ω ≤ R < 2 Ω
2 Ω ≤ R < 20 Ω
20 Ω ≤ R < 200 Ω
200 Ω ≤ R < 2 kΩ
2 kΩ ≤ R < 20 kΩ
20 kΩ ≤ R < 110 kΩ
110 kΩ ≤ R < 200 kΩ
200 kΩ ≤ R < 2 MΩ
2 MΩ ≤ R < 20 MΩ
20 MΩ ≤ R < 200 MΩ
200 MΩ ≤ R < 2 GΩ
2 GΩ ≤ R ≤ 10 GΩ

Multímetros, Medidores, Indicadores de temperatura por termoresistencia

0 Ω ≤ R < 0,001 Ω
0,001 Ω ≤ R < 2 Ω
2 Ω ≤ R < 20 Ω
20 Ω ≤ R < 200 Ω
200 Ω ≤ R < 2 kΩ
2 kΩ ≤ R < 20 kΩ
20 kΩ ≤ R < 110 kΩ
110 kΩ ≤ R < 200 kΩ
200 kΩ ≤ R < 2 MΩ
2 MΩ ≤ R < 20 MΩ
20 MΩ ≤ R < 200 MΩ
200 MΩ ≤ R ≤ 1 GΩ

Multímetros, Medidores, Indicadores genéricos con
entrada de resistencia

0 Ω ≤ R ≤ 10 Ω
10 Ω < R ≤ 100 Ω
100 Ω < R ≤ 1 kΩ
1 kΩ < R ≤ 10 kΩ
10 kΩ < R ≤ 100 kΩ
100 kΩ < R ≤ 1 MΩ
1 MΩ < R ≤ 10 MΩ

TEMPERATURA POR SIMULACIÓN ELÉCTRICA

Indicadores y simuladores de
temperatura para termopares
tipo R

0 °C a < 110 °C
110 °C a 1767 °C

Indicadores y simuladores de
temperatura para termopares
tipo K

-200 °C a < -166 °C
– 166 °C a 1372 °C

Indicadores y simuladores de
temperatura para termopares
tipo N

– 200 °C a 160 °C
> 160 °C a 1300 °C

Indicadores y simuladores de
temperatura para termopares
tipo T

– 250 °C a < -210 °C
– 210 °C a < -150 °C
– 150 °C a 400 °C

Indicadores y simuladores de
temperatura para termopares
tipo E

– 250 °C a < -200 °C
-200 °C a 1000 °C

Indicadores y simuladores de
temperatura para termopares
tipo S

0 °C a < 120 °C
120 °C a 1767 °C

Indicadores y simuladores de
temperatura para termopares
tipo J

– 210 °C a < -166 °C
-166 °C a 1200 °C

VELOCIDAD ANGULAR

Tacómetros ópticos

0,1 Hz ≤ f ≤ 1700 Hz

 

 

Mass / Scale

Pesas de clase E2 o inferior calidad según OIML‐R111

1 mg
2 mg
5 mg
10 mg
20 mg
50 mg
100 mg
200 mg
500 mg
1 g
2 g
5 g
10 g
20 g
50 g
100 g
200 g
500 g

Pesas de clase F1 o inferior calidad según OIML‐R111

1 kg
2 kg
5 kg
10 kg
20 kg

Patrones de masas no acordes a OIML R 111

1 mg
2 mg
3 mg
5 mg
10 mg
20 mg
30 mg
50 mg
100 mg
200 mg
300 mg
500 mg
1 g
2 g
3g
5 g
10 g
20 g
30 g
50 g
100 g
200 g
300 g
500 g
1 kg
2 kg
3 kg
5 kg
10 kg
20 kg
30 kg

Medidas de masa

1 mg
2 mg
5 mg
10 mg
20 mg
50 mg
100 mg
200 mg
500 mg
1 g
2 g
3g
5 g
10 g
20 g
50 g
100 g
200 g
500 g
1 kg
2 kg
3 kg
5 kg
10 kg
20 kg
32 kg

MASA CONVENCIONAL

Instrumentos de pesaje de
funcionamiento no automático
(IPFNA): Básculas y balanzas
monoplato.

1 mg ≤ m ≤ 5 mg
5 mg < m ≤ 50 mg
50 mg < m ≤ 500 mg
500 mg < m ≤ 2 g
2 g < m < 1 kg
1 kg ≤ m ≤ 80 kg
80 kg < m ≤ 1225 kg
1225 kg < m ≤ 3500 kg (2)

Instrumentos de pesaje de
funcionamiento no automático
(IPFNA) con receptores de
carga especiales tipo tolva,
depósito, silo, gancho, reactores.

1 g < m < 50 g
50 g ≤ m ≤ 75 kg
75 kg < m ≤ 1225 kg
1225 kg < m ≤ 10000 kg (2)

Instrumentos de pesaje de
funcionamiento automático
(IPFA) Seleccionadoras
ponderales, cintas pesadoras

1 mg ≤ m ≤ 50 mg
50 mg < m ≤ 500 mg
500 mg < m ≤ 2 g
2 g < m < 1 kg
1 kg ≤ m ≤ 75 kg
75 kg < m ≤ 1225 kg

Pressure / Vacuum

PRESIÓN RELATIVA HIDRÁULICAPRESIÓN RELATIVA HIDRÁULICA

Manómetros, Transmisores, Transductores, Presostatos

0 MPa ≤ P ≤ 4 MPa
4 MPa < P ≤ 100 MPa

Manómetros, Transmisores, Transductores, Presostatos

0 MPa ≤ P ≤ 100 MPa

PRESIÓN RELATIVA NEUMÁTICA

Manómetros, Transmisores, Transductores, Columnas de
Líquido, Presostatos

-100 kPa ≤ P < -1 kPa
-1 kPa ≤ P ≤ 1 kPa
1 kPa < P ≤ 0,7 MPa
0,7 MPa < P ≤ 7 MPa

Manómetros, Transmisores, Transductores, Columnas de
Líquido, Presostatos

-100 kPa ≤ P < -1 kPa
-1 kPa ≤ P ≤ 1 kPa
1 kPa < P ≤ 2 MPa

PRESIÓN ABSOLUTA NEUMÁTICA

Manómetros, Transmisores, Transductores, Columnas de
Líquido, Presostatos

0 kPa ≤ P ≤ 55 kPa
55 kPa < P ≤ 117 kPa
117 kPa < P ≤ 0,8 MPa
0,8 MPa < P ≤ 7 MPa

Manómetros, Transmisores, Transductores, Columnas de
Líquido, Presostatos

0 kPa ≤ P ≤ 80 kPa
80 kPa < P ≤ 117 kPa
117 kPa < P ≤ 2,1 MPa

Temperature

TEMPERATURA

Termómetros de
lectura directa
con sensor de
resistencia
Termómetros de
resistencia de
Platino
Transmisores de
Temperatura
(##)

– 80 ˚C a 80 ˚C
>80 ˚C a 270 ˚C
>270 ˚C a 400 ˚C

Termómetros de
lectura directa
con sensor de
termopar de
metal común
Termómetros de
lectura directa
con sensor de
termopar de
metal noble

– 80 ˚C a 400 ˚C
>400 ˚C a 700 ˚C
>700 ˚C a 1100 ˚C

Termopares de
metal noble

0 ˚C a 400 ˚C
>400 ˚C a 700 ˚C
>700 ˚C a 1100 ˚C

Termopares de
metales
comunes

80 ˚C a 400 ˚C
>400 ˚C a 700 ˚C
>700 ˚C a 1100 ˚C

Termómetros de
lectura directa
con sensor de
resistencia
Termómetros de
resistencia de
Platino
Transmisores de
temperatura
(##)

-80 ˚C a 70 ˚C
>70 ˚C a 165 ˚C
>165 ˚C a 400 ˚C

Termómetros de
lectura directa
con sensor de
termopar de
metales
comunes
Termómetros de
lectura directa
con sensor de
termopar de
metal noble

-80 ˚C a 165 ˚C
>165 ˚C a 400 ˚C
>400 ˚C a 700 ˚C
>700 ˚C a 1100 ˚C

Termopares de
metal noble

0˚C a 400 ˚C
>400˚C a 700 ˚C
>700˚C a 1100˚C

Termopares de
metales
comunes

-80˚C a 400 ˚C
>400˚C a 700 ˚C
>700˚C a 1100˚C

TEMPERATURA (SIMULACIÓN ELÉCTRICA)

Indicadores y
convertidores de
temperatura con
entrada para
sensor de
resistencia
termométrica
(##)

-200 ˚C a 850 ˚C

Indicadores y
convertidores de
temperatura con
entrada para
termopares de
metal común
(compensación
interna) (##)

-200 ˚C a 1200 ˚C

Indicadores y
convertidores de
temperatura con
entrada para
termopares de
metal noble
(compensación
interna) (##)

200 ˚C a 1200 ˚C

Indicadores y
convertidores de
temperatura con
entrada
analógica (##)

-200 ˚C a 1100 ˚C

TEMPERATURA EN AIRE

Termómetros de
lectura directa
con sensor de
resistencia.
Transmisores de
temperatura (##)

-45 ˚C a 5˚C
>5˚C a 45˚C
>45˚C a 100˚C
>100˚C a 145˚C

Termómetros de
lectura directa
con sensor de
termopar de
metal común
Transmisores de
temperatura (##

-45 ˚C a 5˚C
>5˚C a 45˚C
>45˚C a 100˚C
>100˚C a 145˚C

Termómetros de
lectura directa
con sensor de
resistencia
termométrica
Transmisores de
temperatura
(##)

15 ˚C a 23˚C
>23˚C a 45˚C

Termómetros de
lectura directa
con sensor de
termopar de
metal común
Transmisores de
temperatura (##)

15 ˚C a 23˚C
>23˚C a 45˚C

 

Time/Frequency

INTERVALO DE TIEMPO

Cronómetros, Medidores de
intervalos de tiempo

1 s ≤ ≤t ≤ 86400 s

Cronómetros, Medidores de
intervalos de tiempo

1 s ≤ ≤t ≤ 86400 s

Torque

PAR DE TORSIÓN

Herramientas dinamométricas
(en sentido dextrógiro)

0,1 N · m ≤ M ≤ 1000 N · m

Comprobadoras de par (en
sentido dextrógiro y levógiro)

0,1 N · m ≤ M ≤ 25 N · m

Herramientas dinamométricas
(en sentido dextrógiro)

1 N · m ≤ M ≤ 1000 N · m

Comprobadoras de par (en
sentido dextrógiro y levógiro)

1 N · m ≤ M ≤ 25 N · m

Volume

VOLUMEN

Aparatos volumétricos operados por pistón
(Micropipetas tipo pistón, buretas tipo pistón,
diluidores, dispensadores y jeringas)

0,1µl ≤ V ≤ 2 µl
2 µl < V ≤ 10 µl
10 µl < V ≤ 20 µl
20 µl < V ≤ 50 µl
50 µl < V ≤ 100 µl
100 µl < V ≤ 100 ml

Aparatos volumétricos operados por pistón
(Micropipetas tipo pistón, buretas tipo pistón,
diluidores, dispensadores y jeringas)

0,1 µl ≤ V ≤ 2 µl
2µl < V ≤ 10 µl
10 µl < V ≤ 20 µl
20 µl < V ≤ 50 µl
50 µl < V ≤ 100 µl
100 µl < V ≤ 100 ml

Aparatos volumétricos no accionados por
pistón. (Buretas, Pipetas de uno o dos aforos de
volumen fijo, Pipetas graduadas, Matraces aforados, Probetas graduadas y Picnómetros tipo matraz)

0,01 ml ≤ V ≤ 0,5 ml
0,5 ml < V ≤ 1 ml
1 ml < V ≤ 2 ml
2 ml < V ≤ 5 ml
5 ml < V ≤ 10 ml
10 ml < V ≤ 25 ml
25 ml < V ≤ 50 ml
50 ml < V ≤ 100 ml
100 ml < V ≤ 200 ml
200 ml < V ≤ 250 ml

250 ml < V ≤ 500 ml
500 ml < V ≤ 1000 ml

Thermal and climatic testing

CALIBRADORES DE BLOQUE SECO

Estudio de estabilidad de temperatura
-80 ˚C a 270 ˚C (Incertidumbre: ± 0,040 ˚C)
>270 ˚C a 400 ˚C (Incertidumbre: ± 0,040 ˚C)
>400 ˚C a 700 ˚C (Incertidumbre: ± 1,2 ˚C)
>700 ˚C a 1100 ˚C (Incertidumbre: ± 1,5 ˚C)
Estudio de uniformidad de temperatura
-80 ˚C a 270 ˚C (Incertidumbre: 0,060 ˚C)
>270 ˚C a 400 ˚C (Incertidumbre: ± 0,070 ˚C)
>400 ˚C a 700 ˚C (Incertidumbre: ± 1,8 ˚C)
>700 ˚C a 1100 ˚C (Incertidumbre: ± 2,2 ˚C)
Estudio de indicación de temperatura
-80 ˚C a 270 ˚C (Incertidumbre: ± 0,10 ˚C)
>270 ˚C a 400 ˚C (Incertidumbre: ± 0,18 ˚C)
>400 ˚C a 700 ˚C (Incertidumbre: ± 3,0 ˚C)
>700 ˚C a 1100 ˚C (Incertidumbre: ± 3,7 ˚C)

Estudio de estabilidad de temperatura
-80 ˚C a 250 ˚C (Incertidumbre: ± 0,15 ˚C)
>250 ˚C a 400 ˚C (Incertidumbre: ± 1,8 ˚C)
>400 ˚C a 700 ˚C (Incertidumbre: ± 1,9 ˚C)
>700 ˚C a 1100 ˚C (Incertidumbre: ± 2,2 ˚C)
Estudio de uniformidad de temperatura
-80 ˚C a 250 ˚C (Incertidumbre: ± 0,20 ˚C)
>250 ˚C a 400 ˚C (Incertidumbre: ± 1,9 ˚C)
>400 ˚C a 700 ˚C (Incertidumbre: ± 3,0 ˚C)
>700 ˚C a 1100 ˚C (Incertidumbre: ± 4,0 ˚C)
Estudio de indicación de temperatura
-80 ˚C a 250 ˚C (Incertidumbre: ± 0,35 ˚C)
>250 ˚C a 400 ˚C (Incertidumbre: ± 3,6 ˚C)
>400 ˚C a 700 ˚C (Incertidumbre: ± 4,7 ˚C)
>700 ˚C a 1100 ˚C (Incertidumbre: ± 6,8 ˚C)

BAÑOS DE TEMPERATURA CONTROLADA

Estudio de estabilidad de temperatura
-80 ˚C a 270˚C (Incertidumbre: ± 0,040˚C)
Estudio de uniformidad de temperatura
-80 ˚C a 270˚C (Incertidumbre: ± 0,060˚C)
Estudio de indicación de temperatura
-80 ˚C a 270˚C (Incertidumbre: ± 0,1 ˚C)

Estudio de estabilidad de temperatura
-80 ˚C a 250 ˚C (Incertidumbre: ± 0,15 ˚C)
Estudio de uniformidad de temperatura
-80 ˚C a 250 ˚C (Incertidumbre: ± 0,20 ˚C)
Estudio de indicación de temperatura
-80 ˚C a 250 ˚C (Incertidumbre: ± 0,35 ˚C)

Estudio de estabilidad de temperatura
-80 ˚C a 250 ˚C (Incertidumbre: ± 0,15 ˚C)
Estudio de uniformidad de temperatura
-80 ˚C a 250 ˚C (Incertidumbre: ± 0,20 ˚C)
Estudio de indicación de temperatura
-80 ˚C a 250 ˚C (Incertidumbre: ± 0,45 ˚C)

AUTOCLAVES DE ESTERILIZACIÓN (Presión hasta 0,5 MPa)

Estudio de estabilidad de temperatura
20 ˚C a 140 ˚C (Incertidumbre: ± 0,30 ˚C)
Estudio de uniformidad de temperatura
20 ˚C a 140 ˚C (Incertidumbre: ± 0,35 ˚C)
Estudio de indicación de temperatura
20 ˚C a 140 ˚C (Incertidumbre: ± 0,65 ˚C)

HORNOS, MUFLAS

Estudio de estabilidad de temperatura
20 ˚C a 250 ˚C (Incertidumbre: ± 1,4 ˚C)
>250 ˚C a 700 ˚C (Incertidumbre: ± 1,7 ˚C)
>700 ˚C a 1100 ˚C (Incertidumbre: ± 2,2 ˚C)
Estudio de uniformidad de temperatura
20 ˚C a 250 ˚C (Incertidumbre: ± 1,6 ˚C)
>250 ˚C a 700 ˚C (Incertidumbre: ± 3,1 ˚C)
>700 ˚C a 1100 ˚C (Incertidumbre: ± 4 ˚C)
Estudio de indicación de temperatura
20 ˚C a 250 ˚C (Incertidumbre: ± 2,7 ˚C)
>250 ˚C a 700 ˚C (Incertidumbre: ± 4,8 ˚C)
>700 ˚C a 1100 ˚C (Incertidumbre: ± 6,0 ˚C)

ESTUFAS

Estudio de estabilidad de temperatura
20 ˚C a 250 ˚C (Incertidumbre: ± 0,15 ˚C)
>250 ˚C a 300 ˚C (Incertidumbre: ± 1,7 ˚C)
Estudio de uniformidad de temperatura
20 ˚C a 250 ˚C (Incertidumbre: ± 0,25 ˚C)
>250 ˚C a 300 ˚C (Incertidumbre: ± 3,1 ˚C)
Estudio de indicación de temperatura
20 ˚C a 250 ˚C (Incertidumbre: ± 0,45 ˚C)
>250 ˚C a 300 ˚C (Incertidumbre: ± 4,8 ˚C)

INCUBADORES

Estudio de estabilidad de temperatura
20 ˚C a 50 ˚C (Incertidumbre: ± 0,15 ˚C)
Estudio de uniformidad de temperatura
20 ˚C a 50 ˚C (Incertidumbre: ± 0,20 ˚C)
Estudio de indicación de temperatura
20 ˚C a 50 ˚C (Incertidumbre: ± 0,45 ˚C)

CONGELADORES

Estudio de estabilidad de temperatura
-80 ˚C a 0 ˚C (Incertidumbre: ± 0,15 ˚C)
Estudio de uniformidad de temperatura
-80 ˚C a 0 ˚C (Incertidumbre: ± 0,30 ˚C)
Estudio de indicación de temperatura
-80 ˚C a 0 ˚C (Incertidumbre: ± 0,60 ˚C)

REFRIGERADORES E INSTALACIONES FRIGORÍFICAS

Estudio de estabilidad de temperatura
0 ˚C a 20˚C (Incertidumbre: ± 0,15 ˚C)
Estudio de uniformidad de temperatura
0 ˚C a 20˚C (Incertidumbre: ± 0,20 ˚C)
Estudio de indicación de temperatura
0 ˚C a 20˚C (Incertidumbre: ± 0,50 ˚C)

CÁMARAS CLIMÁTICAS

Estudio de estabilidad de temperatura
-80 ˚C a 180 ˚C (Incertidumbre: ± 0,15 ˚C)
Estudio de uniformidad de temperatura
-80 ˚C a 180 ˚C (Incertidumbre: ± 0,21 ˚C)
Estudio de indicación de temperatura
-80 ˚C a 180 ˚C (Incertidumbre: ± 0,37 ˚C)

Estudio de estabilidad de humedad relativa
20 %hr a 83 %hr
(Temperatura de 5 ˚C a 23 ˚C)
(Incertidumbre: ± 0,55 %hr a 2.1 %hr) (función lineal)
15 %hr a 83 %hr
(Temperatura de >23˚C a 45˚C)
(Incertidumbre: ± 0.40 %hr a 1.6 %hr) (función lineal)
Estudio de uniformidad de humedad relativa
20 %hr a 83 %hr
(Temperatura de 5 ˚C a 23˚C)
(Incertidumbre: ± 0.70 % hr a 3 % hr) (función lineal)
15 %hr a 83 %hr
(Temperatura de >23˚C a 45˚C)
(Incertidumbre: ± 0,40 %hr a 1.9 %hr) (función lineal)
Estudio de indicación de humedad relativa
20 %hr a 83 %hr
(Temperatura de 5 ˚C a 23˚C)
(Incertidumbre: ± 1.2 %hr a 4.4%hr) (función lineal)
15 %hr a 83 %hr
(Temperatura de >23˚C a 45˚C)
(Incertidumbre: ± 0,70 %hr a 3 %hr) (función lineal)

SALAS CLIMATIZADAS

Estudio de estabilidad de temperatura
15 ˚C a 70 ˚C (Incertidumbre: ± 0,15 ˚C)
Estudio de uniformidad de temperatura
15 ˚C a 70 ˚C (Incertidumbre: ± 0,21 ˚C)
Estudio de indicación de temperatura
15 ˚C a 70 ˚C (Incertidumbre: ± 0,37 ˚C)

Estudio de estabilidad de humedad relativa
20 %hr a 83 %hr
(Temperatura de 10˚C a 23 ˚C)
(Incertidumbre: ± 0,30 %hr a 0,8 %hr) (función lineal)
15 %hr a 83 %hr
(Temperatura de >23˚C a 45˚C)
(Incertidumbre: ± 0,20 %hr a 0,7 %hr) (función lineal)
Estudio de uniformidad de humedad relativa
20 %hr a 83 %hr
(Temperatura de 10 ˚C a 23˚C)
(Incertidumbre: ± 0,40 %hr a 2,3 %hr) (función lineal)
15 %hr a 83 %hr
(Temperatura de >23˚C a 45˚C)
(Incertidumbre: ± 0,2 %hr a 1,5 %hr) (función lineal)
Estudio de indicación de humedad relativa
20 %hr a 83 %hr
(Temperatura de 10 ˚C a 23˚C)
(Incertidumbre: ± 0,9 %hr a 3,4%hr) (función lineal)
15 %hr a 83 %hr
(Temperatura de >23˚C a 45˚C)
(Incertidumbre: ± 0,6 %hr a 2,6 %hr) (función lineal)

TERMOCICLADORES

Estudio de estabilidad de temperatura
30 ˚C a 95 ˚C (Incertidumbre: ± 0,20 ˚C)
Estudio de uniformidad de temperatura
30 ˚C a 95 ˚C (Incertidumbre: ± 0,25 ˚C)
Estudio de indicación de temperatura
30 ˚C a 95 ˚C (Incertidumbre: ± 0,50 ˚C)

Optics

DENSIDAD ÓPTICA DE TRANSMITANCIA (Absorbancia)

Espectrofotómetros UV-VIS

(λ = 235 nm, λ = 257 nm, λ = 313nm
y λ = 350 nm)
0,03 < A ≤ 0,04
(ácido perclórico 0,001 M)
0,09 < A ≤ 0,29
(dicromato de potasio 20 mg/l)
0,19 < A ≤ 0,58
(dicromato de potasio 40 mg/l)
0,29 < A ≤ 0,88
(dicromato de potasio 60 mg/l)
0,38 < A ≤ 1,16
(dicromato de potasio 80 mg/l)
0,48 < A ≤ 1,45
(dicromato de potasio 100 mg/l)
(valores nominales, filtros de
dicromato de potasio y ácido
perclórico)
(λ = 440 nm)
A = 0,3 y A = 0,5
A = 1,0
(λ = 465 nm y λ = 546,1 nm)
A = 0,3; A = 0,5 y A = 1,0
(λ = 590 nm)
A = 0,3 y A = 0,5
A = 1,0
(λ = 635 nm)
A = 0,3; A = 0,5 y A = 1,0
(valores nominales, filtros de vidrio
de densidad neutra)

LONGITUD DE ONDA (279 nm a 640 nm)

Espectrofotómetros
UV-VIS

λ =279,3 nm, λ =360,8 nm,
λ =453,4 nm, λ = 536,4 nm,
λ =637,5 nm
(óxido de holmio)

HUMEDAD

Higrómetros de humedad relativa
Transmisores de humedad relativa
(##)
NOTA: Con límite de temperatura de punto de rocío
de -20 ˚C

10 %hr a 50 %hr
(5 ˚C a 23 ˚C)
>50 %hr a 95 %hr
(5 ˚C a 23 ˚C)
10 %hr a 50 %hr
(>23 ˚C a 60 ˚C)
>50 %hr a 95 %hr
(>23 ˚C a 45 ˚C)
>50 %hr a 95 %hr
(>45 ˚C a 60 ˚C)

Higrómetros de humedad relativa
Transmisores de humedad (##)

20 %hr a 50 %hr
(15 ˚C a 23 ˚C)
>50 %hr a 80 %hr
(15 ˚C a 23 ˚C)
15 %hr a 80 %hr
(>23 ˚C a 45 ˚C)

CONTACT
Trescal
Barcelona ASSI - Spain
ASSI Sistemas e Instrumentación, SL, Calle Ramón Martí i Alsina 2-6, plantas 2 y 3. 08911 Badalona
+34 93 540 03 48
Sales
Valentín Martinez
+34 628 76 94 86
Recruitment
RRHH